Waterproof Legionnaire's or Legionella thermometer kit - IP66/67

Waterproof Legionnaires' or Legionella Thermometer Kit - IP66/67

£0.00 In Stock Sold out

Waterproof Legionnaires' Thermometer Kit or Legionella thermometer kit with IP66/67 Therma Waterproof thermometer.  This Waterproof Legionella testing thermometer kit can be used to monitor the temperature of both standing water and the surface of pipes and tanks that form part of the water system. The penetration probe can also be used to test the temperature of tap water. The immersion probe should be placed in the water to a minimum depth of 25mm; the ribbon surface probe may be used to take the temperature of pipes and tanks, and the wire probe can be used to reach awkward places or where the other probes are not appropriate.

This kit comes with a traceable certificate of calibration. Incorrect water temperature is a key risk factor for legionella growth. Legionella bacteria multiply in water at temperatures between 20 to 45°C, particularly if a supply of nutrients is present, such as scale, rust, sludge or algae. A typical method of control is to store cold water below 20°C. Hot water should be stored above 60°C and distributed at above 50°C. Current legislation means that if you are the employer or person in control of premises, you must organise a risk assessment. The revised Approved Code of Practice (ACOP) issued by the Government's Health and Safety Executive (HSE) significantly extends the scope of its guidance on control of legionella bacteria in water.

The code now applies to all hot and cold water systems in the workplace regardless of their capacity, i.e. the lower limit of 300 litres previously used to exclude domestic systems no longer applies. Whilst domestic systems may represent a risk, the code only applies to risk arising from a work activity.

This means that all employers who manage premises with hot/cold water systems and/or a wet cooling system have a legal responsibility to identify any risk of contamination and to prevent or control it. Each Waterproof Legionella thermometer kit contains: For full details on the Therma Waterproof thermometer click here! If you are the employer or person in control of premises, you must organise a risk assessment from exposure to legionella. The revised Approved Code of Practice (ACOP) Legionnaires' disease: Control of Legionella Bacteria in water systems (L8) issued by the Government's Health and Safety Executive (HSE) significantly extends the scope of its guidance on control of legionella bacteria in water. The code applies to all hot and cold water systems in the workplace regardless of their capacity, i.e. the lower limit of 300 litres previously used to exclude domestic systems, no longer applies. Whilst domestic systems may represent a risk, the code only applies to a risk arising from a work activity, but does include domestic landlords who have a duty to keep their tenants safe from health hazards.

This means that all employers and landlords, who manage premises with hot/cold water systems and/or wet cooling systems, have a legal responsibility to identify any risk of contamination and to prevent or control it.

range: -99.9 to 299.9°C (at 0.1°C), 300 to 1372°C (at 1°C)
range 0.1°C: -99.9 to 299.9°C
range 1°C: 300 to 1372°C
resolution: 0.1 °C to 299.9°C thereafter 1°C
accuracy: ±0.4°C ±0.1%
battery: 3 x 1.5 volt AAA
battery life: minimum 5 years (10000 hours)
sensor type: K thermocouple
display: 15mm LCD
backlight: Yes
dimensions: 32 x 71 x 141mm
weight: 220 grams
case material: ABS plastic with Biomaster anti-bacterial additive
country of manufacture: United Kingdom
guarantee: two years
water/dust resistance: IP66/67 protection
measurement scale: Celsius
certification: FREE traceable calibration certificate
conforms to standard: EN 13485